KMACS 5

Category:

The KMACS 5 controls diver’s air supply, communications, and monitors the diver’s depth. It allows two divers clear push to talk (two wire) or round robin (four wire) communications.

The air supply can be either from a low pressure compressor or high pressure cylinders. The KMACS 5 adjustable regulator reduces the high-pressure air and supplies low pressure through the umbilical to the diver’s breathing system. High pressure yokes with DIN adapters permit U.S. standard scuba cylinders or DIN valve cylinders to be used. A low pressure air supply fitting allows for a L.P. compressor to be used as the primary air source.

A complete pneumo system with dual reading gauges (both US Standard and Metric) is provided for each diver, as well as a shut-off/bleed system that uses two high pressure feed lines which allows changing of used cylinders without interruption of the diving operation. Shut off valves allow the isolation of each diver’s air supply. The Communication Set is a multipurpose intercommunication system that provides reliable and clear communications between a topside operator (tender) and one or more surface-supported divers, diving bells, personnel transfer capsules (PTC)s, recompression chambers, or other submersible systems. The lightweight, high impact polyethylene plastic case features double wall construction and extra thick corners ensure exceptional strength and a long work life. An O-ring seal protects hardware from moisture when the case is closed. All latches are stainless steel for maximum work life.

Communication Set: A multi-purpose intercommunication system that provides reliable and clear communications

Depth Gauge/Pneumo Systems:
Dual reading gauges are accurate to + 1/4 of 1% of scale, continuously monitoring the diver’s depths from 0-250 FSW (0-78 MSW). Maximum recommended user depth: 130 FSW.

Depth Monitoring/Pneumo Knob: Used to meter the flow of air used for depth measurement.

Stainless Steel Air Outlet Fittings: Connect the diver’s air supply hose and depth monitoring/pneumo hose to the KMACS, providing a strong, reliable, corrosion resistant connection. Shut-off valves allow the isolation of one diver’s air supply from the other.

Regulator Adjustment Knob: Controls the air pressure delivered to the diver’s umbilical. Variable pressure settings from 115 P.S.I. to 225 P.S.I. are obtainable.

Selector Valve Handle: Used to choose either one of the air supply cylinders. Individual cylinders may be changed out with no interruption of the dive.

High Pressure (HP) Supply Gauges: Directly monitor the pressure in each of the air supply cylinders.

Low Pressure Air Supply Fitting: Allows a low pressure compressor to be used as the primary air source. Low Pressure Supply Max. 225 P.S.I.

Umbilical Pressure Gauge: Provides a constant reading of the pressure in the diver’s umbilical. The scale on the gauge is 0-300 P.S.I. (0-20 Bar). Recommended umbilical pressure range 150-225 P.S.I.

High Pressure Air Supply Yokes with DIN fittings: Each yoke has a bleeder valve for rapid cylinder changing. H.P. Supply Max. 4500 P.S.I. (300 Bars)

Weight: 57 pounds

Outer Dimensions: Length = 21 inches, Height = 17 1/2 inches

Operational Specifications & Limitations Use: For SS Air diving only. Pure oxygen MUST NOT be used. Compressed air from high pressure tanks (scuba or other types of compressed air tanks), or from a compressor should be the only supply to the KMACS 5.

Recommended Maximum Dive Support Depth: 130 FSW (feet of sea water) (40 meters)

High Pressure Supply Pressure Maximum: 4500 pounds per square inch (300 Bars)

Low Pressure Supply Pressure Maximum: 225 pounds per square inch (15.5 Bars)

Umbilical Pressure Range: 115-225 pounds per square inch (8-15.5 Bars)

Regulator Output: 40 SCFM at 2500 P.S.I. (172 Bars) supply pressure with 150 P.S.I. (10.3 Bars) delivery pressure

Relief Valve: Set at 300 P.S.I. (20.7 Bars)

Pneumo Fathometer Range: 0-250 FSW (feet of sea water) (0-76 meters)

Communicator (4 wire system): Can also be used in 2 wire mode

Battery Type: Rechargeable, 12 volt system
Battery Performance: 20 hours of continuous use between charges in 4 wire mode

Charger: Will accept external 12 volt source

Communicator Power Output: 8 watts

Communicator Frequency Response: 600 to 12,000 HZ

Remote Operation Capability: Yes, with optional unit

Direct Recording Capability: Yes

KMACS 5 Complete Manual
MK3_KMDSI_Communicator_UserGuide_415-107
KMACS 5 BlowApart Low Resolution
KMACS5 Blowapart High Resolution

Part # Product
AMR 2460-28 Headset w/Boom Mic & Double Banana Plugs
DSI 415-056 Rechargeable Battery
DSI 425-090 KMACS-5 Overhaul Kit
DSI 425-099 KMACS-5 Communication Conversion Kit
DSI 425-120 Regulator Rebuild Kit KMACS 5 DCS
Part # DSI
Sale!

$6,441.75$8,374.75 $0.00$8,374.75