The LP Hankison HF 24 Series filter package includes three-stage filtration for up to 100 CFM (2831 L/min) compressors with a #12 SAE inlet fitting, on/off ball valve and a #12 SAE fitting for a diver's hose.
It is used on our Quincy 370 and Quincy 5120 packages.
Maximum Pressure & Temperature Operating Range
Drain Type | Maximum Operating Pressure | Maximum Operating Temperature | Minimum Operating Temperature |
---|---|---|---|
Drain Plug |
300 psi (21 bar) |
150°F (66°C) | 35°F (2°C) |
Internal Automatic Drain |
250 psi (17 bar) |
150°F (66°C) |
35°F (2°C) |
Drains plugs standard. Externally mounted automatic drains are available.
Performance Data
ISO performance data of the three-stage HF Series filter housing when configured with Grade 1 (Oil Vapor Removal), Grade 5 (High Efficiency Oil Removal), and Grade 7 (Air Line) filter elements:
Element | Removes | ISO 8573.1: 2010 Air Quality Class | Where Used |
---|---|---|---|
Grade 7 |
∙ Solids 1.0 micron and larger |
∙ Solid Particles: Class 2 ∙ Remaining Oil Content: Class 4 |
∙ Upstream of ultra high efficiency oil removal filters ∙ At point-of-use if aftercooler/separator installed upstream |
Grade 5 |
∙ 99.999+% of solids 0.01 micron and larger |
∙ Solid Particles: Class 1 |
∙ Upstream of desiccant dryers ∙ Downstream of refrigerated dryers ∙ At point-of-use if aftercooler/separator installed upstream |
Grade 1 |
∙ Removes 99.9999+% of solids 0.01 micron and larger |
∙ Solid Particles: Class 1 |
∙ Downstream of high efficiency oil removal filters |