Hankison HF 24 Series Filter Packages

SKU:
NU 6063.3

The LP Hankison HF 24 Series filter package includes three-stage filtration for up to 100 CFM (2831 L/min) compressors with a #12 SAE inlet fitting, on/off ball valve and a #12 SAE fitting for a diver's hose.

It is used on our Quincy 370 and Quincy 5120 packages. 

 

Maximum Pressure & Temperature Operating Range

Drain TypeMaximum Operating PressureMaximum Operating TemperatureMinimum Operating Temperature
Drain Plug

300 psi (21 bar)

150°F (66°C) 35°F (2°C)
Internal Automatic Drain

250 psi (17 bar)

150°F (66°C)

35°F (2°C)

Drains plugs standard. Externally mounted automatic drains are available.

 

 

Performance Data

ISO performance data of the three-stage HF Series filter housing when configured with Grade 1 (Oil Vapor Removal), Grade 5 (High Efficiency Oil Removal), and Grade 7 (Air Line) filter elements:

ElementRemovesISO 8573.1: 2010 Air Quality ClassWhere Used
Grade 7

∙ Solids 1.0 micron and larger
∙ Remaining oil content 1 ppm/w

∙ Solid Particles: Class 2
∙ Remaining Oil Content: Class 4
∙ Upstream of ultra high efficiency oil removal filters
∙ At point-of-use if aftercooler/separator installed upstream
Grade 5

∙ 99.999+% of solids 0.01 micron and larger
∙ Remaining oil content <0.008 ppm/w

∙ Solid Particles: Class 1
∙ Remaining Oil Content: Class 1

∙ Upstream of desiccant dryers
∙ Downstream of refrigerated dryers
∙ At point-of-use if aftercooler/separator installed upstream 
Grade 1

∙ Removes 99.9999+% of solids 0.01 micron and larger
∙ Remaining oil content <0.003 ppm/w (as a vapor)

∙ Solid Particles: Class 1
∙ Remaining Oil Content: Class 1

∙ Downstream of high efficiency oil removal filters

 